Skip to content
Skip to content
Welcome to Perfect Pollucon Services Office Hours: 10:00am-7:00pm
Perfect Pollucon Services

Perfect Pollucon Services

Environmental Consultant & Laboratory

Call Us 9967436537
Mail Us [email protected]
Maharashtra, India 3 Krishna Koyna B, Majiwada, Thane W
  • Home
  • Monitoring Services
    • Ambient Air Quality Monitoring & Testing
    • Indoor Air Quality Monitoring & Testing
    • Air Quality Monitoring & Testing
    • Stack Emission Monitoring & Testing
    • Noise Level Monitoring & Testing
    • Food Testing Laboratory Services
    • Fugitive Emission Monitoring & Testing
    • Soil Testing & Investigation Laboratory
    • Drinking Water Quality Testing & Analysis Laboratory
    • Corrosion Testing Services
    • Illumination Survey / Lux Monitoring
    • Ventilation Survey
  • Consultancy Services
    • Environmental Impact Assessment
    • Environmental Statement Form V
    • MPCB Consent to Establish, Operate and Renewal
    • Operation and maintenance of Effluent Treatment Plant
    • Effluent Treatment Plant Design
    • Six Monthly EC Compliance Report
    • Self Audit Report MPCB
    • Environmental Compliance
  • Industries
    • Pharmaceutical Industries
    • Chemical and Petrochemical Industry
    • Construction & Real Estate
    • Oil and Gas Or Petroleum Industry
    • Manufacturing / Production Industry
    • Corrosion Control at Data Center / IT Industry
    • Mining and Mineral Extraction
    • Food & Cold Storage Industry
    • Supply Chain & Warehouses
    • Data Centres
    • Railways & Metro Projects
    • Hospitality & Tourism
    • Retail and Shopping Malls
  • Blog
  • Tools
    • Air Monitoring Calculators
    • Stack Monitoring Calculators
    • Noise Monitoring Calculators
    • Carbon & Energy Footprint Calculators
    • Lux & Illuminance Calculators
    • ETP & STP Calculators for Form-V
    • ETP Design Calculators
  • About Us
    • Vision
    • Why We Built EHSSaral?
    • Our Work and Clients
    • Case Studies
    • Testimonials & Leave Us a Review
    • Trusted Partners
    • Careers
    • Guest Posting – Write for Us
    • Press Release
    • Our Features
  • Contact Us
REQUEST A QUOTE

Optimize Your ETP & STP Performance with Precision

Environmental compliance isn’t just about checking boxes-it’s about staying one step ahead. Whether you’re managing daily operations, preparing for audits, or submitting Form-V, accuracy is everything. That’s why we’ve created this free suite of ETP/STP calculators-designed especially for EHS professionals, plant managers, and environmental consultants.

ETP & STP Calculators for Form-V help you quickly:

  • Measure treatment efficiency
  • Monitor pollutant loads
  • Optimize chemical dosing
  • Prepare compliance reports like Form-V and water balance sheets

All calculators follow industry-accepted formulas and are crafted to give instant clarity, reduce manual errors, and save valuable time during compliance reporting.

🔍 About ETP & STP Calculators for Form-V Calculators

  • ✅ No login required
  • ✅ Free to use – created by Perfect Pollucon Services’ compliance experts
  • ✅ Easy to understand & mobile-friendly
  • ✅ Based on MPCB & CPCB guidelines
  • ✅ More calculators coming soon!

💧 ETP & STP Calculators for Form-V: ETP Efficiency Calculator

Description:

The ETP Efficiency Calculator helps evaluate the performance of your Effluent Treatment Plant by calculating the percentage removal efficiency of key pollutants like BOD, COD, or TSS. It helps identify whether your treatment process is working within the norms prescribed by regulatory bodies such as MPCB.

Formula:

Efficiency (%) = [(Inlet – Outlet) / Inlet] × 100

Use Cases

  • Quickly assess plant performance during audits or daily checks.
  • Demonstrate compliance with regulatory discharge norms.
  • Identify operational issues or need for chemical dosing adjustments.
  • Helps in preparing Form-V environmental statement reports.

ETP Efficiency Calculator

Calculate pollutant removal efficiency (%) of your ETP based on inlet and outlet concentrations.

Efficiency: —%

We benchmark against the CPCB’s environmental protection guidelines each quarter.

💧 ETP Inlet Load Calculator

Description:

The ETP Inlet Load Calculator estimates the daily pollutant load (in kg/day) entering your Effluent Treatment Plant. It calculates the mass of contaminants like BOD, COD, or TSS based on flow rate and concentration.

This value is essential to assess whether the treatment plant is receiving a load within its design limits and to plan for performance optimization or upgrades.

Formula:

Pollutant Load (kg/day) = Flow (m³/day) × Concentration (mg/L) × 0.001

Use Cases:

  • Monitor if ETP is being under or over-loaded
  • Evaluate capacity utilization of your treatment system
  • Identify high pollution days or peak loading issues
  • Required for Form-V, consent renewal, and environmental audits

ETP Inlet Load Calculator

Estimate the daily pollutant load (kg/day) entering your ETP based on flow and concentration.

Pollutant Load: — kg/day

Read our Comprehensive guide to step by step process to fill Form V enviromental statement or Environmental audit before 30th sep Every year

⚗️ ETP & STP Calculators for Form-V: Chemical Dosing Calculator (Alum / Lime / Ferric)

Description:

This Chemical Dosing Calculator helps you determine the quantity of coagulants (like Alum, Lime, or Ferric Chloride) required for your ETP/STP based on your flow rate and target dosage.

It’s essential for maintaining treatment efficiency, avoiding under/overdosing, and ensuring consistent pollutant removal without unnecessary chemical costs.


Formula:

Dosing Required (kg/day) = Flow (m³/day) × Dosage (mg/L) × 0.001


Use Cases:

  • Plan daily chemical requirements based on actual flow
  • Optimize procurement and inventory of treatment chemicals
  • Avoid manual errors in shift logbooks
  • Support budget estimation and operational cost tracking

Chemical Dosing Calculator

Calculate the required daily dosing quantity (in kg) for common treatment chemicals like Alum, Lime, or Ferric.

Required Chemical Dose: — kg/day

Explore the books that shaped the green movement—our environmental book recommendations are timeless.

🚰 Water Balance Calculator

Description:

The Water Balance Calculator helps industries and commercial units estimate and visualize their daily water usage, recycling, and discharge. It’s crucial for preparing water balance diagrams for MPCB consents, Form-V submissions, and sustainability reports.


Formula:

Water Used = Fresh Water + Recycled Water
Water Discharged = Total Used – Reused in Process


Use Cases:

  • Generate water budget for MPCB consent/renewal
  • Evaluate % of treated water reuse vs discharge
  • Justify ETP/STP capacity and recycling claims
  • Aid in Form-V and ESG documentation

Water Balance Calculator

Calculate total water usage, reuse, and discharge to build your water budget.

Total Water Used: — m³/day

Estimated Discharge: — m³/day

🧪 Sludge Volume Index (SVI) Calculator

Description:

The Sludge Volume Index (SVI) Calculator helps you assess the settleability of activated sludge in the aeration tank. It’s a key indicator of whether your biological treatment is working efficiently and if there are problems like sludge bulking or poor settling.


Formula:

SVI (mL/g) = Settled Sludge Volume (mL/L) / MLSS (g/L)


Use Cases:

  • Diagnose sludge bulking or filamentous growth
  • Tune return sludge flow (RAS) settings
  • Prevent clarifier overflows or carryover
  • Maintain stable biological treatment in ETP/STP

Sludge Volume Index (SVI) Calculator

Calculate SVI to understand sludge settling characteristics and biological process health.

SVI: — mL/g

🌊 ETP/STP Overflow Risk Estimator

Description:

This calculator helps estimate whether your ETP/STP tank is at risk of overflowing based on incoming flow, tank volume, and retention time. It’s especially helpful during monsoons or when production increases temporarily.


Formula:

Risk = Inlet Flow × Retention Time > Tank Volume → High Risk


Use Cases:

  • Predict overflow risk during peak load or rain
  • Adjust pumping rate or operating time accordingly
  • Prevent environmental violations and property damage
  • Useful during audits or HAZOP studies

Overflow Risk Estimator

Estimate overflow risk of your ETP/STP based on flow rate, tank volume, and retention time.

Result: —

🚨 Discharge Norm Violation Predictor

Description:

This calculator helps you predict if your treated effluent or sewage discharge may violate MPCB discharge limits based on recent lab results or daily sampling. It uses a running average approach to identify potential risks before a violation is reported.


Formula:

Average Concentration = (Value₁ + Value₂ + … + Valueₙ) / n
Compare Average vs Limit → Predict Violation


Use Cases:

  • Proactive compliance before lab audit or sample pickup
  • Detect quality drift in COD/BOD/TSS over time
  • Prevent environmental notices and consent complications
  • Use for weekly internal self-checks

Discharge Norm Violation Predictor

Check if your average outlet value exceeds MPCB norms using recent sample values.

Average Value: — mg/L

Status: —

💸 Recycled Water ROI Calculator

Description:

This calculator helps EHS professionals estimate the cost savings and return on investment (ROI) from reusing treated water instead of consuming fresh municipal or borewell water. It’s especially valuable when proposing sustainability upgrades, STP recycling systems, or for green building certifications.


Formula:

Monthly Savings = Recycled Water Used (m³) × Fresh Water Rate (₹/m³)
ROI (%) = (Monthly Savings × 12) / Annual Recycling System Cost × 100


Use Cases:

  • Justify STP/ETP reuse projects to top management
  • Prepare for ISO 14001, ESG, or green audits
  • Highlight CSR/environmental impact
  • Compare recycling investment vs tanker/fresh water costs

Recycled Water ROI Calculator

Estimate monthly savings and ROI from reusing treated water instead of using fresh supply.

Monthly Savings: ₹—

Annual ROI: —%

💰 ETP/STP Operational Cost Estimator

Description:

This calculator estimates the monthly and annual operational cost of running your ETP or STP based on electricity usage, manpower, chemical consumption, and lab testing frequency. It’s a go-to tool for budgeting, vendor comparisons, and internal planning.


Formula:

Total Cost = Power Cost + Manpower + Chemicals + Testing Charges


Use Cases:

  • Create an annual ETP/STP O&M budget
  • Compare costs across facilities or vendors
  • Justify automation to reduce operating cost
  • Use for ISO 14001, sustainability & finance planning

ETP/STP Operational Cost Estimator

Estimate the monthly and annual cost of operating your ETP or STP based on common inputs.

Monthly O&M Cost: ₹—

Annual O&M Cost: ₹—

🏗️ ETP/STP Capacity Expansion Justifier

Description:

This calculator helps you assess whether your current ETP/STP capacity is sufficient based on peak daily flow, MPCB consented flow, and actual plant capacity. It flags overload risks and estimates required expansion.


Formula:

  • Overload (%) = (Peak Flow – Plant Capacity) / Plant Capacity × 100
  • Consent Gap = Peak Flow – MPCB Consented Quantity

Use Cases:

  • Predict overload conditions based on production growth
  • Support AMC renegotiation or plant expansion proposals
  • Avoid MPCB violations from exceeding consented flow
  • Build ROI cases for civil/mechanical upgrades

ETP/STP Capacity Expansion Justifier

Check if your current plant capacity can handle peak flow and stay within MPCB consent limits.

Overload Status: —

Consent Limit Status: —

🧱 Sludge Generation Estimator

Description:

This calculator estimates the quantity of sludge generated in your ETP or STP based on daily flow, percentage of suspended solids removed, and assumed solids content in dewatered sludge. It helps plan de-sludging, transport, and filter press schedules.


Formula:

Sludge (kg/day) = Flow × SS Removed (mg/L) × 0.001
Dewatered Sludge (m³/day) = Sludge (kg/day) / Solids % / 1000


Use Cases:

  • Estimate daily or weekly sludge volume for planning
  • Schedule de-sludging and disposal
  • Forecast hazardous waste quantities for Form-3
  • Avoid overflow in sludge drying beds or filter press backlog

Read more about Step by Step guide for Hazardouse waste Return Form IV

Sludge Generation Estimator

Estimate the daily sludge generation based on SS removal and flow rate.

Dry Sludge: — kg/day

Dewatered Sludge Volume: — m³/day

Ready to Level Up Your Compliance Game?

Whether you’re preparing your Environmental Statement (Form-V), facing an audit, or just want to run your ETP/STP smarter – these free calculators are your secret weapon. Built by compliance experts at Perfect Pollucon Services, they’re fast, accurate, and designed for real-world use.

  • 📉 Reduce manual errors in reporting
  • 📊 Simplify Form-V, Water Balance, Sludge, and Pollutant Load calculations
  • 🧪 Stay ahead of MPCB/CPCB norms

Bookmark this page. Use it monthly. Share it with your EHS team.

📥 Need help interpreting your results or want Form-V support? Get in touch with our environmental experts.

🔗 Useful Resources for ETP & STP Calculators for Form-V

  • CPCB guidelines on wastewater treatment and ETP design
  • Environmental rules and Form-V requirements under Environment Protection Act, 1986
  • MPCB Consent to Operate and Environmental Statement (Form-V) procedures
  • National Green Tribunal’s role in environmental compliance
  • What is an ETP? A detailed overview by TERI
  • Official Environment (Protection) Rules governing Form-V submissions
  • NITI Aayog’s guide on STP technologies and reuse strategies

0 / 180

Environmental Monitoring Services

  • Ambient Air Quality Monitoring & Testing
  • Indoor Air Quality Monitoring & Testing
  • Air Quality Monitoring & Testing
  • Fugitive Emission Monitoring & Testing
  • Stack Emission Monitoring & Testing
  • Food Testing Laboratory Services
  • Noise Level Monitoring & Testing
  • Corrosion Testing Services
  • Ventilation Survey
  • Illumination Survey

Search

Download Our Brochure (682 kb)

Download Our Company Brochure

WhatsApp Chat with Perfect Pollucon Expert

Recent Posts

  • Dehumidifier Maintenance & Cleaning Tips for Indian Homes | Expert Guide by PPS
  • Understanding Ideal TDS, Hardness & Microbial Load in Water
  • Dehumidifier vs Air Purifier vs Humidifier: Expert Indian Guide
  • IAQ Testing for LEED & WELL Building | PPS Expert Guide
  • EC Compliance Report 2025 – Expert PPS Guide
  • RO vs UV vs UF Water Purifier: Which is Better in India?
  • Best Water Purifiers for Home in India (2025) – Lab Tested Reviews
  • How to Fill E-Waste Form 3 Annual Return (Step-by-Step)
  • SPCB Environmental Compliance Forms – The Ultimate Guide
  • How to Fill Form 10 Hazardous Waste Manifest -Step-by-Step Guide

Environmental Consultancy Services

  • Environmental Monitoring and Assessment
  • Environmental Impact Assessment
  • Effluent Treatment Plant
  • Effluent Treatment Plant Design
  • Consent to Establish, Consent to Operate and Renewal
  • Six Monthly EC Compliance Report
  • Self Audit Report MPCB
  • Environmental Compliance in India
  • Ventilation Survey
  • Tools
  • HTML Sitemap

Environmental Consultancy Services

  • Environmental Monitoring and Assessment
  • Environmental Impact Assessment
  • Effluent Treatment Plant
  • Effluent Treatment Plant Design
  • Consent to Establish, Consent to Operate and Renewal
  • Six Monthly EC Compliance Report
  • Self Audit Report MPCB
  • Environmental Compliance in India
  • Ventilation Survey
  • Tools
  • HTML Sitemap

Environmental Monitoring Services

  • Ambient Air Quality Monitoring & Testing
  • Indoor Air Quality Monitoring & Testing
  • Air Quality Monitoring & Testing
  • Fugitive Emission Monitoring & Testing
  • Stack Emission Monitoring & Testing
  • Food Testing Laboratory Services
  • Noise Level Monitoring & Testing
  • Corrosion Testing Services
  • Ventilation Survey
  • Illumination Survey

About Us

  • Home
  • Blog
  • Our Vision & Mission
  • About Us
  • Case Studies
  • Industries We Serve
  • Write for Us | Guest Posting
  • Privacy Policy
  • Terms and Conditions
  • Explore our EnviroTech platform: EHSSaral.com

Registered Office

Perfect Pollucon Services – Environmental Consultancy Company
3 Krishna Koyna B, Majiwada Thane,
Maharashtra, India
400601
Email: [email protected]
Phone :
+91 9137 039 315
+91 9930 180 059
+91 7045 651 859
Perfect Pollucon Services (proprietorship firm reg. 2009) is now Perfect Pollucon LLP (CIN : ACP-2349) (reg in Jun’2025)

  • Privacy Policy
  • Terms and Conditions
  • Contact Our Experts
  • Sitemap
@Copyright Perfect Pollucon Services
Free ETP & STP Calculators for Form-V & Compliance | PPS